PDP200AE0130 — Modine Power Vented Gas Unit Heater
| Heating Capacity (Input) |
200,000 BTU/hr |
| Heating Capacity (Output) |
166,000 BTU/hr |
| Thermal Efficiency |
82% |
| Fuel Type |
Natural Gas (field convertible to LP) |
| Ignition System |
Intermittent pilot with continuous retry |
| Venting Configuration |
Power vented, 180° rotation (vertical/horizontal) |
| Voltage / Phase / Hertz |
115V / 1 / 60Hz |
| Amperage Draw |
5.15 amps |
| Circuit Breaker Requirement |
15 amp |
| Motor Horsepower |
0.17 HP |
| Airflow (CFM) |
2,870 CFM |
| Output Velocity |
819 FPM |
| Discharge Air Temperature Rise |
52°F |
| Heat Throw Distance |
51 feet |
| Maximum Mounting Height |
15 feet |
| Installation Type |
Ceiling Mount (Vertical or Horizontal) |
| Gas Connection Size |
1/2 inch NPT |
| Vent Connection Size |
5 inch diameter |
| Safety Features |
100% shut-off, pressure switch, time delay relay |
| Construction Material |
Aluminized Steel |
| Dimensions (W x D x H) |
25.625″ x 25″ x 40.25″ |
| Net Weight |
239 lbs |
| Clearances (Top/Side/Access) |
5″ / 1″ / 18″ |
| Bottom Clearance to Floor |
12 inches |
| Flue Connector Clearance |
7 inches |
| Optional Accessories |
Deflector hoods, high altitude kits, two-stage valve |
| Warranty |
10 years |
| Country of Origin |
USA |
Power Venting and Installation Flexibility for the PDP200AE0130
The Modine PDP200AE0130 features a power exhauster that rotates 180 degrees for vertical or horizontal venting, adapting to facility layouts without requiring orientation-specific models.
The 5-inch vent diameter minimizes back pressure while maintaining proper draft, and the smallest-diameter specification reduces material costs and roof penetration complexity. With only 5 inches of top clearance and 1 inch to side walls, the unit fits into constrained mechanical spaces where larger heaters cannot be installed.
The adjustable hanging mechanism allows field-level corrections after accessories are added, maintaining proper balance without reinstallation.
Maximum mounting height of 15 feet and 51-foot heat throw cover warehouses, manufacturing floors, and large commercial spaces.
The 2870 CFM airflow at 819 FPM output velocity circulates air without uncomfortable drafts, while optional 30-, 60-, or 90-degree deflector hoods direct heat into specific work areas.
Ignition System and Safety Controls
The intermittent pilot-ignition system with continuous retry eliminates manual resets after failed attempts. The controller cycles three ignition attempts at six-minute intervals before lockout, then automatically resumes after one hour.
This continuous retry prevents downtime in unmanned facilities where temporary pressure fluctuations might otherwise require service calls.
The 100% shut-off gas valve prevents unburned gas accumulation if pilot flame is not detected. The automatic reset vent pressure switch monitors exhaust for restrictions and prevents burner operation until blockages are cleared.
A time delay relay postpones blower start for 30 to 90 seconds during startup to prevent cold air discharge, then runs the motor after shutdown to extract residual heat from the aluminized steel heat exchanger.
Field Conversion and Commercial Applications
The PDP200AE0130 ships configured for natural gas but converts to liquid propane using a dedicated LP kit. Conversion involves replacing the burner orifice, adjusting gas valve pressure, and recalibrating ignition timing. This eliminates the need for fuel-specific models and allows switching if natural gas service becomes available or propane pricing improves.
The 82% thermal efficiency reflects aluminized steel heat exchanger construction, collector box design, and power exhauster that maintains optimal combustion ratios.
The 115V electrical requirement connects to standard 15-amp branch circuits without dedicated 208V or 240V service.
Support and Availability
Heinlein Supply stocks the Modine PDP200AE0130 and related replacement components including blower motors, burner assemblies, and ignition controls for same-day shipping on orders placed before 3 pm.
Our technical staff can verify gas supply compatibility, calculate venting configurations, and recommend accessories for your mounting height and coverage needs.
Contact our experts to verify specifications and get current lead times on PDP200AE0130 units.